sales@engineeringcomputation.com
- SOLIDCastCasting Simulation Software
- MT ExchangeHeat Exchanger Software
- MT VessPressure Vessel Design Software
- PIPEFLOPipeline Design Software
- WELLFLOOil & Gas Wells Design Software
- FORGASGas Field Deliverability Forecasting and Development Scheduling System
- OmniSuitePlanning and Scheduling Softwares
- CAST-DESIGNER™A Gating System Designer For High Pressure Die Casting Process
- CYMDISTDistribution System Analysis
- PSAFPower Systems Analysis Framework
- EMTP-RVElectromagnetic Transient Program
- CYMGRDSubstation Grounding Program
- CYMTCCProtective Device Coordination
- CYMCAPCable Ampacity Calculation
- SORPAS®Resistance Welding Simulation Software
- ProTeusComputerized Maintenance Management System
- QForm-ExtrusionExtrusion Simulation and Optimisation Software
- Electromagnetic Software3D Electromagnetic Field Calculations
CYMDIST (HARMO)
Harmonic Analysis
OverviewCYMDIST (HARMO) is an add-on module to CYMDIST designed to perform harmonic penetration analysis in electric distribution systems.
CYMDIST(HARMO) features a number of analyses, including frequency scan, voltage distortion and current distortion calculations on balanced and unbalanced systems. CYMDIST-HARMO allows the user to easily detect resonant frequencies due to capacitor banks, and to model non-linear loads and other sources of harmonic currents such as converters and arc furnaces. With these capabilities, it is possible to evaluate the impact of these non-linear loads on your distribution network.
It is specifically designed for utility-type grids and distribution feeders of any configuration.
CYMDIST (HARMO) utilizes state of the art sparse matrix/vector methods with a three-phase nodal admittance network matrix representation.
The frequency scan can be performed at any joint of a feeder by simply selecting the desired section directly in the one-line-diagram and running the analysis.
CYMDIST (HARMO) allows the users to model multiple types of harmonic sources to compute the effectiveness of filters and modify them at will in order to attain acceptable level of harmonic distortion on your network:
* Ideal and non-ideal converters* Arc furnaces
* Single-tuned and double-tuned filters
* C-type filters
* High-pass filters
* User-defined shunt single and multi frequency sources
Analytical Capabilities
* Voltage Harmonic Distortion
* Current Harmonic Distortion
* Impedance vs. frequency analysis
* Phase or sequence analysis
* Calculation of telephonic indices (TIF, ITIF, etc.)
* Selection of line/cable models: series R-L, nominal PI, transposed distributed parameters, etc.
* System detuning analysis
- CYMDIST (MAP) - Geographic Overlay
- CYMDIST (SNA) - Secondary Network Analysis
- CYMDIST (SUB / SUBNET) - Substation / Subnetwork Modeling and Analysis
- CYMDIST (CAM) - Contingency Analysis Module
- CYMDIST (RAM) - Reliability Assessment
- CYMDIST (SOM) - Switching (Tie Point) Optimization Module
- Energy Profile Manager - Energy Profile Manager
- CYMDIST Advanced Project Manager - Advanced Project Manager
- CYMDIST Network Forecaster - CYMDIST Network Forecaster
